Safety and documents
Rules for using the generator, safeguards that work without your involvement, and documents you can see before you buy.
Warnings
The device shows the same warnings on its screen. Read them before you switch the generator on for the first time.
Hydrogen is an extremely flammable gas
Mixed with air it can form an explosive mixture.
No smoking. No open flame
Keep the device and cannula away from sparks, flames and hot surfaces.
Ensure ventilation
Do not use the device in a small closed room. Do not cover the ventilation openings.
Do not collect the gas
Do not fill containers or bags with the gas. Do not let gas escape and build up in the room.
Distilled or demineralised water only
Tap or mineral water damages the membrane. Such damage is not covered by the warranty.
Earthed 230 V socket
Switch off and unplug before opening the housing or replacing the fuse.
Operating conditions
0–40 °C, humidity below 85 %, level surface, no direct sunlight.
Transport without water
Drain all the water from the tank before transport.
Cannula hygiene
Each person uses their own cannula. Replace it regularly.
Read the manual before use
Do not leave children unattended near the device.
Four everyday rules
Tube first
Before starting, remove the cap from the gas outlet and connect the tube. Do not start gas production without the tube connected and do not touch the outlet.
Always upright
Do not lay the device on its side or upside down. Empty the tank before transport. Do not put objects on the casing, especially liquids.
No oil or grease
No part should come into contact with oil or grease. The tubes must be clear, with no kinks or twists.
Repairs only by the service centre
Do not dismantle or repair the device yourself. This risks electric shock or fire.
Codes on the display
Each of the eight codes means that the device has stopped gas production by itself.
| Code | What it means | What to do |
|---|---|---|
| E0 | PEM membrane failure | Switch off the device and contact the service centre. |
| E1 | Overheating | Leave the device to cool down. Check that the rear fan is working and that the air outlets are not covered. |
| E2 | Water level sensor fault | Switch off the device and contact the service centre. |
| E3 | Poor water quality, “Bad” indicator | Empty the tank, rinse it with distilled or purified water and refill it. |
| E4 | Water level too low | Add about 1500 ml of distilled or purified water. |
| E5 | Excessive tilt | Place the device on a flat, level surface. |
| E6 | Too much water in the tank | Open the drain, connect the drain tube and let out the excess water. |
| E7 | Blocked gas tube | Check that the tube is not kinked or blocked. |
Hydrogen was well tolerated in studies
In a safety study, 8 healthy adults breathed air with 2.4% hydrogen continuously for 24, 48 or 72 hours. No clinically significant adverse events occurred. In a multicentre trial with a hydrogen-oxygen mixture, adverse events were reported less often than in the oxygen-only group: 63% versus 78%.
The longest periods of daily inhalation described are about half a year. The main risk is physical: with air, hydrogen forms a flammable mixture in the range from 4 to 75%.
What the studies say
Selected scientific publications on molecular hydrogen in humans: a description of each study, its results and a link to the source.
1Safety of long inhalation in healthy adults
no control groupn = 8inhalation2021
Safety of long inhalation in healthy adults
- Participants
- 8 healthy adults aged 18–30
- Protocol
- 2.4% H2 in medical air through a high-flow cannula (15 l/min) for 24, 48 or 72 hours in hospital conditions
- Result
- All completed the study. The inhalation was well tolerated: vital signs, lung function, ECG and blood tests remained stable, with no clinically significant adverse events.
- Study context
- Prospective safety study, one group (phase I). Participants: 8.
Cole AR i wsp.. Safety of prolonged inhalation of hydrogen gas in air in healthy adults. Critical Care Explorations 3(10): e543. 2021. PubMed 34651133 · DOI · Full text
2Exacerbation of COPD
randomised trialn = 107inhalation2021
Exacerbation of COPD
- Participants
- 108 randomised; 107 in the full analysis set
- Protocol
- H2/O2 2:1 vs oxygen for 7 days, alongside standard treatment
- Result
- BCSS fell by 5.3 vs 2.4 points; adjusted difference −2.75 points (95% CI −3.27 to −2.22). CAT score: −11 vs −6 points (p<0.001).
- Study context
- RCT, 10 centres, double-blind. Participants: 107.
Zheng ZG i wsp.. Hydrogen/oxygen therapy for the treatment of an acute exacerbation of chronic obstructive pulmonary disease: results of a multicenter, randomized, double-blind, parallel-group controlled trial. Respiratory research 22(1): 149. 2021. PubMed 33985501 · DOI · Full text
Educational information, not medical advice. Full database of publications: Hydrogen Studies.
What you can see before you buy
EU declaration of conformity
The Low Voltage, Electromagnetic Compatibility and RoHS Directives.
Electrical safety
Testing to EN 60335-1 and measurement of electromagnetic fields to EN 62233 in an external laboratory.
Gas composition
Analysis of the gas at the outlet by gas chromatography in an external laboratory.
User manual
In six languages (PDF), with a description of the error codes, maintenance and warranty terms.
We send the documents on request. Write to us.