# Safety and documents

> Safety rules for the PRAGMA HYDROGEN hydrogen generator, self-diagnosis codes, data from inhalation safety studies and documents.

URL: https://pragmah2.com/en/safety/
Updated: 2026-11-20

Rules for using the generator, safeguards that work without your involvement, and documents you can see before you buy.

Before first use

## Warnings

The device shows the same warnings on its screen. Read them before you switch the generator on for the first time.

- ### Hydrogen is an extremely flammable gas
  Mixed with air it can form an explosive mixture.
- ### No smoking. No open flame
  Keep the device and cannula away from sparks, flames and hot surfaces.
- ### Ensure ventilation
  Do not use the device in a small closed room. Do not cover the ventilation openings.
- ### Do not collect the gas
  Do not fill containers or bags with the gas. Do not let gas escape and build up in the room.
- ### Distilled or demineralised water only
  Tap or mineral water damages the membrane. Such damage is not covered by the warranty.
- ### Earthed 230 V socket
  Switch off and unplug before opening the housing or replacing the fuse.
- ### Operating conditions
  0–40 °C, humidity below 85 %, level surface, no direct sunlight.
- ### Transport without water
  Drain all the water from the tank before transport.
- ### Cannula hygiene
  Each person uses their own cannula. Replace it regularly.
- ### Read the manual before use
  Do not leave children unattended near the device.

[Download the user manuals](https://pragmah2.com/manuals/?lang=en)

From the user manual

## Four everyday rules

#### Tube first

Before starting, remove the cap from the gas outlet and connect the tube. Do not start gas production without the tube connected and do not touch the outlet.

#### Always upright

Do not lay the device on its side or upside down. Empty the tank before transport. Do not put objects on the casing, especially liquids.

#### No oil or grease

No part should come into contact with oil or grease. The tubes must be clear, with no kinks or twists.

#### Repairs only by the service centre

Do not dismantle or repair the device yourself. This risks electric shock or fire.

Self-diagnosis

## Codes on the display

Each of the eight codes means that the device has stopped gas production by itself.

| Code | What it means | What to do |
| --- | --- | --- |
| E0 | PEM membrane failure | Switch off the device and contact the service centre. |
| E1 | Overheating | Leave the device to cool down. Check that the rear fan is working and that the air outlets are not covered. |
| E2 | Water level sensor fault | Switch off the device and contact the service centre. |
| E3 | Poor water quality, “Bad” indicator | Empty the tank, rinse it with distilled or purified water and refill it. |
| E4 | Water level too low | Add about 1500 ml of distilled or purified water. |
| E5 | Excessive tilt | Place the device on a flat, level surface. |
| E6 | Too much water in the tank | Open the drain, connect the drain tube and let out the excess water. |
| E7 | Blocked gas tube | Check that the tube is not kinked or blocked. |

### When to talk to a doctor first

People with chronic conditions, pregnant women and children should consult a doctor before use.

### Hygiene

Each person uses their own cannula. In a practice, the cannula is always new.

---

What is known from studies

## Hydrogen was well tolerated in studies

In a safety study, 8 healthy adults breathed air with 2.4% hydrogen continuously for 24, 48 or 72 hours. No clinically significant adverse events occurred. In a multicentre trial with a hydrogen-oxygen mixture, adverse events were reported less often than in the oxygen-only group: 63% versus 78%.

The longest periods of daily inhalation described are about half a year. The main risk is physical: with air, hydrogen forms a flammable mixture in the range from 4 to 75%.

What the studies say

Selected scientific publications on molecular hydrogen in humans: a description of each study, its results and a link to the source.

**1 Safety of long inhalation in healthy adults no control group n = 8 inhalation 2021**

- **Participants**: 8 healthy adults aged 18–30
- **Protocol**: 2.4% H2 in medical air through a high-flow cannula (15 l/min) for 24, 48 or 72 hours in hospital conditions
- **Result**: All completed the study. The inhalation was well tolerated: vital signs, lung function, ECG and blood tests remained stable, with no clinically significant adverse events.
- **Study context**: Prospective safety study, one group (phase I). Participants: 8.

Cole AR i wsp.. *Safety of prolonged inhalation of hydrogen gas in air in healthy adults*. Critical Care Explorations 3(10): e543. 2021. [PubMed 34651133](https://pubmed.ncbi.nlm.nih.gov/34651133/) · [DOI](https://doi.org/10.1097/CCE.0000000000000543) · [Full text](https://pmc.ncbi.nlm.nih.gov/articles/PMC8505337/)

**2 Exacerbation of COPD randomised trial n = 107 inhalation 2021**

- **Participants**: 108 randomised; 107 in the full analysis set
- **Protocol**: H2/O2 2:1 vs oxygen for 7 days, alongside standard treatment
- **Result**: BCSS fell by 5.3 vs 2.4 points; adjusted difference −2.75 points (95% CI −3.27 to −2.22). CAT score: −11 vs −6 points (p<0.001).
- **Study context**: RCT, 10 centres, double-blind. Participants: 107.

Zheng ZG i wsp.. *Hydrogen/oxygen therapy for the treatment of an acute exacerbation of chronic obstructive pulmonary disease: results of a multicenter, randomized, double-blind, parallel-group controlled trial*. Respiratory research 22(1): 149. 2021. [PubMed 33985501](https://pubmed.ncbi.nlm.nih.gov/33985501/) · [DOI](https://doi.org/10.1186/s12931-021-01740-w) · [Full text](https://pmc.ncbi.nlm.nih.gov/articles/PMC8120708/)

Educational information, not medical advice. Full database of publications: [Hydrogen Studies](https://hydrogenstudies.com/dataset).

[Guide: safety of hydrogen inhalation](https://pragmah2.com/en/knowledge-base/inhalation-safety/)

FLAMMABILITY IN NUMBERS

- **Flammable range in air**: 4–75%
- **Hydrogen from a one-hour session**: approx. 60 l
- **Concentration in a 30 m³ room with no air exchange**: approx. 0.2%

The risk concerns the immediate surroundings of the outlet and the cannula, which is why flames and sparks are prohibited near the device.

Documents

## What you can see before you buy

#### EU declaration of conformity

The Low Voltage, Electromagnetic Compatibility and RoHS Directives.

#### Electrical safety

Testing to EN 60335-1 and measurement of electromagnetic fields to EN 62233 in an external laboratory.

#### Gas composition

Analysis of the gas at the outlet by gas chromatography in an external laboratory.

#### User manual

In six languages (PDF), with a description of the error codes, maintenance and warranty terms.

We send the documents on request. [Write to us.](https://pragmah2.com/en/contact/)

**A device for wellness use** PRAGMA HYDROGEN is a device for wellness use, intended for indoor use. It is not a medical device.

**Responsible entity and contact for product safety matters** PRAGMA Prosta Spółka Akcyjna, ul. Piotrkowska 46 m. 8U, 90-265 Łódź, info@pragmah2.com. Model H2/O2 (1500), type PS-V1. The device is not a toy: do not let children operate it unsupervised.

[Order for PLN 17,990](https://pragmah2.com/en/order/)